TENS and EMS Units
In order to purchase a TENS or EMS unit you are required to submit a
prescription from your medical provider before we can ship your unit.
Click here for a printable form to use for your prescription
|
 |
TENS-2000
(with safety cover)
3 Mode without Timer
Channels: Dual, Isolated between channels
Modes: Burst, Constant, Modulation
Pulse Width: 60 to 250 microseconds,
adjustable
Pulse Amplitude (intensity): 0 to 80 mA each
channel, adjustable (500 ohm load)
Pulse Frequency: 2 to 150 Hz adjustable
Modulation Mode: Pulse width automatically
varies is a cyclical pattern over an
interval of nominally 4 seconds
Burst Mode: 7 pulses per burst, 2
bursts per second, 100Hz
internal frequency of burst
Battery Life: 70 hour average (alkaline)
Waveform: Modified square wave
with zero net direct current
* All values have +/- 10% tolerance
$52.95
|
|
 |
TENS-2500
(with safety cover)
3 Mode with Timer
Channels: Dual, Isolated between channels
Modes: Burst, Constant, Modulation
Pulse Width: 60 to 250 microseconds,
adjustable
Pulse Amplitude (intensity): 0 to 80 mA each
channel, adjustable (500 ohm load)
Pulse Frequency: 2 to 150 Hz adjustable
Timer: 30 Min, 60 Min, or Constant
Modulation Mode: Pulse width automatically
varies is a cyclical pattern over an
interval of nominally 4 seconds
Burst Mode: 7 pulses per burst, 2
bursts per second, 100Hz
internal frequency of burst
Battery Life: 70 hour average (alkaline)
Waveform: Modified square wave
with zero net direct current
* All values have +/- 10% tolerance
$56.50
|
|
 |
TENS 6000
(with safety cover)
Digital TENS with Timer
Channels: Dual
Modes: Burst, Normal, MRW, SD, Bi-Pulse
Pulse Width: 50-300 microseconds,
adjustable
Pulse Amplitude: 0 to 80 mA each channel
Pulse Frequency: Variable, 2-150 Hz
Waveform: Asymmetric biphasic square
pulse
Timer: 5 to 90 Min, or constant time
Compliance Timer: 60 sets of operation
records, 999 hours record time
* All values have +/- 10% tolerance
$72.85
|
|
 |
EMS-3000
(with safety cover)
Muscle Stimulator
Channels: Dual, Isolated between channels
Modes: Burst, Constant, Modulation
Pulse Amplitude: 0 to 100 mA Peak
at 500 s/channel
Pulse Frequency: Adjustable,
2-120 Hz
Cycle On/Off: 1-30 sec.
On Ramp: Adjustable 1-8 sec.
Battery Life: Approx. 70 hours
Waveform: Modified square wave with
zero net direct current
* All values have +/- 10% tolerance$57.25
|
|
 |
EMS 6500
(with safety cover)
Digital EMS with Timer
Channels: Dual
Modes: Synchronous (S), Constant (C), and
Alternate (A)
Pulse Amplitude: 0 to 80 mA peak into
500 ohm load each channel, adjustable
Pulse Frequency: 2 to 120 Hz
Pulse Ramp: 1 to 8 seconds
Contraction: Variable Control (2-99 Sec)
Relaxation: Variable Control (2-99 Sec)
Waveform: Asymmetric biphasic square
pulse wave with zero net direct current
Compliance Timer: 60 sets of operation
records, 999 hours record time
* All values have +/- 10% tolerance
$72.85
|
|
 |
IF-4250
Interferential Stimulator
Channel: Dual
Pulse Width: 125 microseconds for each phase
Pulse Amplitude: Adjustable 0-50 mA peak
at 500 S/channel
Carrier Frequency: 4000 Hz fixed
Difference Frequency: (1 +/- 0.5) ~
(250+/-10%) Hz adjustable
Interference Frequency: Channel B
Auto Sweep: 4-45 bps, 80-150 bps,
4-set
Constant Mode: 4-400 bps, adjustable
Waveform: Symmetrical Biphasic Square
Four Frequency Shift: Continuous, 1/1
abrupt, 8/8 abrupt,
10/10 ramped
$205.00
|
|
 |
PGS-123
Pulsed-Galvanic Stimulator
Channel: Single
Output Mode: Synchronous or Alternation.
Alternation mode-LED alternates between green and red color
Pulse Rate: 2-100 Hz
Wave Form: Positive or negative wave form
Pulse Duration: 5 ms
IntraPulse Interval: 100 ms.
All values have +/- 20% tolerance$205.00
|
|
 |
Micro-850
Microcurrent Stimulator (with safety cover)
Channels: Dual
Output Waveform: Modified square DC biphasic pulses of 0.3Hz,
8Hz, and 80Hz changing polarity at intervals of 1 seconds.
Timer: 20, 40 minutes and constant
Frequency: 0.3, 8 and 80Hz
Output Voltage: 12 Volts
All values have a +/- 10% tolerance
$65.75
|
|
 |
IF-2206
Digital Interferential w/True Sine Wave
Channels: Dual, Isolated between channels
Pulse Amplitude: Adjustable, 0-60mA into
500 ohm each channel
Carrier Frequency: 4000 Hz fixed
Waveform: Symmetrical Balanced Sine Wave
Sweep Time: 15 sec.
Frequency Function Mode: Constant, Auto Sweep, Frequency Shift
Output Configuration: Quadra polar (4 electrodes)
Patient Lock System: Yes
Pulse Duration: 125 bps max.
Timer: 15, 30
* All values have +/- 10% tolerance$205.00
|
|
Click here for a printable form to use for your prescription
Kappa Medical, Inc.
PO Box 11808
Prescott, AZ 86304
1-928-778-0840 phone
1-928-776-9250 fax
kappamedical@aol.com
|